Standard configuration: | ECG, NIBP, SpO2, HR/PR, 2-RESP, 2-TEMP, rechargeable battery. |
Optional configuration: | Built-in printer, Nellcor SpO2,2-IBP, ETCO2(main stream or side stream), CO, AG,Wireless network, Wall Mount, Moving cart, 12 volts Power supply |
Feature:
15’’ color TFT LCD screen, High brightness,Wide viewing, 12 waveforms can be displayed on the same screen . lightness and volume are adjustable independently.
Multi-language interface selection: Chinese, English, Spanish, Portuguese, French, Arabic, Russian, Italian, Turkish, etc.
Low-power consumption design with standby mode, rechargeable high-energy built-in battery.
Advanced digital technology, accurately measure SpO2 in low perfusion situation.
Drug calculation, ST-segment detection
Applications in bedside and delivery monitoring; Widely used in patient room, emergency room, operation room, PACU, ICU, CCU, etc.
WAN communication function to network with central monitoring system and make long-distance monitoring, diagnosis, maintenance and software upgrade possible.
Specifications:
ECG | Lead output: 3 wires/5 wires ECG cable Lead section: I, II, III, aVR, aVL, aVF, V Gain selection: ×1/4, ×1/2, ×1, ×2, ×4 and automatic Scan speed: 6.25 mm/s 、12.5 mm/s 、25 mm/s、50mm/s Heart rate range: 15-300bpm ECG calibration: ± 1 mvHeart rate accuracy: ± 1% |
NIBP | Philosophy: Oscillometric method Measurement type: adult, pediatric, neonate Measurement parameter: Systolic, Diastolic, Mean Measurement method: manual, automatic, continuous measurement Unit: mmHg/kPa selectable Accuracy: ±2 or 3mmHg |
SpO2 | Display type: Waveform, data Measurement range: 0~100% Resolution: 1 BPM Pulse rate range: 30~250bpm Accuracy: ±1bpm |
Temperature | Number of channel: 2 channels, measure surface and cavity temperature simultaneously Resolution: 0.1℃ Display: T1, T2, △T |
Respiration | Thoracic impedance & nasal tube double method selectable Measurement range: 0~120bpm Accuracy: ±1bpm Resolution: 1bpm |
ETCO2 (Option) | Measuring Method: main/side stream typeMeasurement range: 0%-10.0% Accuracy: ±2mmHg |
2-IBP (Invasive blood pressure) (Option) | Measurement range: -10-300mmHgChannel: max 4 channels Accuracy:±1mmHg or ±2%Transducer sensitivity: 5uV/V/mmHg Pressure label: ART、CVP、RVP、LAP、RAP、PAP、ICP、LV |
Cardiac Output (Option) | Measuring Method: thermodilution Blood temperature measurement and alarm range: 23 ℃~ 43℃ Unit: degrees Celsius ℃ or Fahrenheit ℉ Resolution: 0.1℃ Cardiac output measurement range: 0.1L/min ~ 20.0 L/min Accuracy: ±0.2 L/min or ±5% Power requirement: 100~240VAC, 50/60Hz |
MOQ:1pc;
CE/ISO/FDA approval;
Standard export carton;